Printed Circuit Board Connector Wiring Diagram Si12-411A
58 Printed Circuit Board Connector Wiring Diagram
1. Printed Circuit Board Connector Wiring Diagram
1.1 Wall Mounted Type 20/25/35 Class
Connectors
Note: Other designations
1) S1 Connector for fan motor
2) S6 Connector for swing motor (Horizontal Flap)
3) S7 Connector for fan motor
4) S21 Connector for centralized control to 5 rooms
5) S26 Connector for signal receiver PCB
6) S27 Connector for control PCB
7) S32 Connector for heat exchanger thermistor
8) S35 Connector for INTELLIGENT EYE Sensor PCB
1) V1 Varistor
2) JA Address setting jumper
JB Fan speed setting when compressor is OFF on thermostat
JC Power failure recovery function
Refer to page 259 for more detail.
3) SW7 Forced operation ON/OFF switch
4) LED1 LED for operation (green)
5) LED2 LED for timer (yellow)
6) LED3 LED for HOME LEAVE operation (red)
7) LED A LED for service monitor (green)
8) FU1 Fuse (3.15A)
9) RTH1 Room temperature thermistor

Table of Contents

Other manuals for Daikin CDKD35CVM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin CDKD35CVM and is the answer not in the manual?

Daikin CDKD35CVM Specifications

General IconGeneral
BrandDaikin
ModelCDKD35CVM
CategoryAir conditioning
LanguageEnglish

Related product manuals