Si12-411A Specifications
Specifications 29
Floor Standing Type
50Hz, 230V
Model FVKS25BVMB FVKS35BVMB
Rated Capacity 2.5kW Class 3.5kW Class
Front Panel Color Almond White Almond White
Air Flow Rates
/min
(cfm)
H 8.1 (286) 8.3 (293)
M 6.2 (219) 6.3 (222)
L 4.3 (152) 4.3 (152)
SL 3.4 (120) 3.4 (120)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 14+14 14+14
Speed Steps 5 Steps, Silent, Auto 5 Steps, Silent, Auto
Air Direction Control Right, Left, Horizontal, Upward Right, Left, Horizontal, Upward
Air Filter Removable-Washable-Mildew Proof Removable-Washable-Mildew Proof
Running Current (Rated) A 0.14 0.14
Power Consumption (Rated) W 32 32
Power Factor % 99.4 99.4
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 600×650×195 600×650×195
Packaged Dimensions (H×W×D) mm 714×770×294 714×770×294
Weight kg 13 13
Gross Weight kg 19 19
Operation
Sound
H/M/L/SL dBA 38/32/26/23 39/33/27/24
Sound Power H dBA 54 55
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ
9.5
φ
9.5
Drain mm
φ
18.0
φ
18.0
Drawing No. 3D040164A 3D040165A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Model FVKS50BVMB
Rated Capacity 5.0kW Class
Front Panel Color Almond White
Air Flow Rates
/min
(cfm)
H 10.8 (381)
M 9.2 (325)
L 7.7 (272)
SL 6.7 (237)
Fan
Type Cross Flow Fan
Motor Output W 14+14
Speed Steps 5 Steps, Silent, Auto
Air Direction Control Right, Left, Horizontal, Upward
Air Filter Removable-Washable-Mildew Proof
Running Current (Rated) A 0.26
Power Consumption (Rated) W 55
Power Factor % 92.0
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 600×650×195
Packaged Dimensions (H×W×D) mm 714×770×294
Weight kg 13
Gross Weight kg 19
Operation
Sound
H/M/L/SL dBA 44/40/36/33
Sound Power H dBA 56
Heat Insulation Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
Gas mm
φ
12.7
Drain mm
φ
20.0
Drawing No. 3D040833

Table of Contents

Other manuals for Daikin CDKD35CVM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin CDKD35CVM and is the answer not in the manual?

Daikin CDKD35CVM Specifications

General IconGeneral
BrandDaikin
ModelCDKD35CVM
CategoryAir conditioning
LanguageEnglish

Related product manuals