5 | Operation
User reference guide
26
EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ
Daikin Altherma 3 R F+W
4P643607-1 – 2021.09
Possible read-out information
In menu… You can read out…
[8.1] Energy data Produced energy, consumed electricity,
and consumed gas
[8.2] Malfunction history Malfunction history
[8.3] Dealer information Contact/helpdesk number
[8.4] Sensors Room temperature, outside
temperature, leaving water
temperature,…
[8.5] Actuators Status/mode of each actuator
Example: Unit pump ON/OFF
[8.6] Operation modes Current operation mode
Example: Defrost/oil return mode
[8.7] About Version information about the system
[8.8] Connection status Information about the connection
status of the unit, the room thermostat
and WLAN.
[8.9] Running hours Running hours of specific system
components
5.6 Space heating/cooling control
5.6.1 About space heating/cooling control
Controlling space heating/cooling typically consists of the following stages:
1 Setting the space operation mode
2 Controlling the temperature
Depending on the system layout and installer configuration, you use a different
temperature control:
▪ Room thermostat control
▪ Leaving water temperature control
▪ External room thermostat control
5.6.2 Setting the space operation mode
About space operation modes
Your unit can be a heating or a heating/cooling model:
▪ If your unit is a heating model, it can heat up a space.
▪ If your unit is a heating/cooling model, it can both heat up and cool down a
space. You have to tell the system which operation mode to use.
To determine if a heating/cooling heat pump model is installed
1 Go to [4]: Space heating/cooling.