8
To copy programmed actions to the next day, proceed as follows:
1 Press the < button.
The actual mode is blinking.
2 Use the pi and pj buttons to select the mode you want
to program.
The selected mode is blinking.
You can leave programming by pressing the pr button.
3 Press the < button to confirm the selected mode.
The actual day is blinking.
4 Select the day you would like to copy to the next day by means
of the pi and pj buttons.
The selected day is blinking.
You can return to step 2 by pressing the pr button.
5 Press the
<
and pr buttons simultaneously for 5 seconds.
After 5 seconds the display will show the next day (e.g. "2" if
"1" was selected first). This indicates that the day has been
copied.
You can return to step 2 by pressing the pr button.
Deleting one or more programmed actions
Deleting one or more programmed actions is done at the same time
as storing the programmed actions.
When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the < button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.
E.g. when the < button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.
Deleting a mode
1 Press the
< butt
on.
The actual mode is blinking.
2 Use the pi and pj buttons to select the mode you want
to delete (current mode or quiet mode s).
The selected mode is blinking.
3 Press the
< and ba button simultaneously for 5
seconds to
delete the selected mode.
Deleting a day of the week (cooling or heating mode)
1 Use the = button to select the operation mode (cooling or
heating) you want to delete.
2 Press the < button.
The actual mode is blinking.
3 Press the < button to confirm the selected mode.
The actual day is blinking.
4 Select the day you would like to delete by means of the pi
and pj buttons.
The selected day is blinking.
5 Press the
< and ba button simultaneously for 5
seconds to
delete the selected day.
3. MAINTENANCE
3.1. Important information regarding the refrigerant
used
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
Refrigerant type: R410A
GWP
(1)
value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
3.2. Maintenance activities
In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals, preferably yearly. This maintenance should be
carried out by your local Daikin technician.
Besides keeping the remote controller clean by means of a soft damp
cloth, no maintenance is required by the operator.
3.3. Standstill
4. TROUBLESHOOTING
The guidelines below, completed by the chapter "Troubleshooting" in
the installatation manual supplied with the unit, might help to solve
your problem. If you cannot solve the problem, consult your installer.
■ No readings on the remote controller (blank display)
Check if the mains power is still connected to your installation.
■ One of the error codes appears
Consult your local Daikin dealer.
■ The schedule timer does work but the programmed actions
are executed at the wrong time (e.g. 1 hour too late or too
early)
Check if the clock and the day of the week are set correctly,
correct if necessary.
■ I cannot enable the schedule timer (the
ee
ee
icon is
displayed)
The schedule timer cannot be enabled because another
component with higher priority is in control.
5. DISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
Do not try to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.
Units must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed off
correctly, you will help to prevent potential negative consequences for
the environment and human health. Please contact the installer or
local authority for more information.
During longer periods of standstill, e.g. during summer with
a heating only application, it is very important NOT TO
SWITCH OFF THE POWER SUPPLY towards the unit.
Switching off the power supply stops the automatic
repetitive movement of the motor in order to prevent it from
getting jammed.
Your product is marked with this symbol. This means