NOTE
You may change the time of indication or
“Time to clean filter”.
If the indoor unit is used in a space where the
air is too contaminated, ask your local dealer
for solution.
Contamination
Time until indication is
displayed
Normal
200 hours
(equivalent to 1 month)
More contaminated
100 hours
(equivalent to 2 weeks)
If it becomes difficult to remove contamination
from the air filter, replace the air filter.
(Air filter for replacement is an optional
accessory)
Increase the frequency of cleaning if the unit is
installed in a room where the air is extremely
contaminated.
8
7. OPTIMUM OPERATION
Observe the following precautions to ensure the air
conditioner operates.
Prevent direct sunlight from the window by
using curtains or blinds during the COOLING
OPERATION.
Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
decrease the effect of cooling and heating.
Never place objects near the air inlet and the air
outlet of the air conditioner. It may decrease the
effect or stop the operation.
Set the airflow flap of the air discharge grille
horizontally not to obstruct the wind.
Otherwise, the wind will not come out and a
failure may result.
Adjust the room temperature properly for a
comfortable environment. Avoid excessive
heating or cooling.
Not doing so wastes electricity.
When the display shows
or “Time to clean
filter”, ask a qualified service person to clean the
filters.
(Refer to 8. MAINTENANCE on this page.)
Operating the indoor unit with stained air filter
may decrease capacity or cause malfunction.
Install TVs, radios, and stereos 1 m or more away
from the indoor unit and remote controller.
Images may become fuzzy and noise may be
generated.
Turn off the power circuit breaker when it is not
in use for a long period. When the power circuit
breaker is turned on, small amount of power is
consumed even if the air conditioner is not in
operation. (*1)
Turn off the power circuit breaker for saving
energy. When reoperating, turn on the power
circuit breaker 6 hours before operation for
smooth running.
(Refer to 8. MAINTENANCE on this page.) (*2)
*1 The consumed power while the outdoor unit is
not in operation depends on the model.
*2 The setting before the power circuit breaker is
cut
off is stored. (The timer setting is cleared.)
Use the TIMER OPERATION effectively.
It takes some time until the indoor temperature
reaches the set temperature. It is advisable to
start operation in advance using the TIMER
OPERATION.
8. MAINTENANCE
(FOR SERVICE PERSONNEL)
ONLY A QUALIFIED SERVICE PERSON IS
ALLOWED TO PERFORM MAINTENANCE
WARNING
Do not useammable gas (such as hair sprays
and insecticides) near the air conditioner.
Do not wipe the air conditioner with benzine
or thinner.
CAUTION
Do not wash the air conditioner with water.
leakage.
Make sure to turn off the air conditioner
when taking care of the air conditioner and
disconnect the power supply breaker.
Unless the power supply is disconnected, it
may cause electric shocks and injuries.
When working at a high place, give caution to
your footing.
If the scaffold is unstable, it may cause injuries
due to fall and stumbling.
HOW TO CLEAN THE AIR FILTER
When the remote controller indicates or
“Time to clean filter”, clean the air filter.
It indicates after running for a certain time.
It may cause cracks, electric shocks or a fire.
It may cause electric shocks or a fire due to