8 Instructions RI8RE3ML © Danfoss 10/2016 AK-CC 210A
Fault code display Alarm code display Status code display
E 1 Fault in controller A 1 High temperature alarm S0 Regulating
E 6 Change battery + check clock A 2 Low temperature alarm S 1 Waiting for end of the coordinated defrost
E 25 S3 sensor error A 4 Door alarm S 2 ON-time Compressor
E 26 S4 sensor error A 5 Max. Hold time S 3 OFF-time Compressor
E 27 S5 sensor error A 15 DI 1 alarm S 4 Drip-off time
A 16 DI 2 alarm S 10 Refrigeration stopped by main switch
A 45 Standby mode S 11 Refrigeration stopped by thermostat
A 59 Case cleaning S 14 Defrost sequence. Defrosting
A 60 HACCP alarm S 15 Defrost sequence. Fan delay
S 17 Door open (open DI input)
S 20 Emergency cooling
S 25 Manual control of outputs
S 29 Case cleaning
S 30 Forced cooling
S 32 Delay of output at start-up
non The defrost temperature cannot be dis-
played. There is stop based on time
-d- Defrost in progress
PS Password required
The buttons
Set menu
1. Push the upper button until a parameter
r01 is shown
2. Push the upper or the lower button and
find that parameter you want to change
3. Push the middle button until the
parameter value is shown
4. Push the upper or the lower button and
select the new value
5. Push the middle button again to enter
the value.
Cutout alarm relay / receipt alarm/see alarm
code
• Push short the upper button
Set temperature
1. Push the middle button until the
temperature value is shown
2. Push the upper or the lower button and
select the new value
3. Push the middle button to select the
setting.
Reading the temperature at defrost sensor
• Push briefly the lower button
Manuel start or stop of a defrost
• Push the lower button for four seconds.
(However, not application 4)
See HACCP registration
1. Give the middle button a long push until
h01 appears
2. Select required h01-h10
3. See value by giving the middle button a
short push
LED
Light emitting diode
= refrigeration
= defrost
= fan running
Flashes fast at alarm
HACCP
HACCP function is active
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep upper and lower button depressed at the same time as you recon nect the supply voltage