6
2. Before attaching the sensor to the cylinder using the
strap provided, connect a 2-core cable to the sensor to
allow interconnection to the thermostat setting unit.
3. Apply the contact paste provided to the part of the
sensor in contact with the cylinder and clamp the sensor
to the cylinder wall.
A spacer piece is provided for use with cylinders that
have thick insulation (see opposite).
4. Mount the thermostat wallplate on to a wall next to the
cylinder. Connect the cable from the sensor to terminals
2 & 3 of the wallplate (see wiring diagram on page 8).
5. Now mount the thermostat setting unit onto the
wallplate and secure using the two screws on the
bottom of the wallplate.
Thermostat installation