7.5Definitions
ThedefinitionsapplytotheECLComfort210/296/310series.
Consequently,youmightcomeacrossexpressionsthatarenot
mentionedinyourguide.
Accumulatedtemperaturevalue
Afiltered(dampened)value,typicallyforroomandoutdoor
temperatures.IscalculatedintheECLcontrollerandisused
toexpresstheheatstoredinthewallsofthehouse.The
accumulatedvaluedoesnotchangesorapidlyastheactual
temperature.
Airducttemperature
Temperaturemeasuredintheairductwherethetemperature
istobecontrolled.
Alarmfunction
Basedonthealarmsettings,thecontrollercanactivateanoutput.
Anti-bacteriafunction
Foradefinedperiod,theDHWtemperatureisincreasedinorder
toneutralizedangerousbacteria,e.g.Legionella.
Balancetemperature
Thissetpointisthebasisfortheflow/airducttemperature.The
balancetemperaturecanbeadjustedbytheroomtemperature,
thecompensationtemperatureandthereturntemperature.The
balancetemperatureisonlyactiveifaroomtemperaturesensor
isconnected.
BMS
B
uildingManagementSystem.Asupervisorysystemforremote
controlandmonitoring.
Comfortoperation
Normaltemperatureinthesystemcontrolledbytheschedule.
Duringheatingtheflowtemperatureinthesystemishigherto
maintainthedesiredroomtemperature.Duringcoolingtheflow
temperatureinthesystemislowertomaintainthedesiredroom
temperature.
Comforttemperature
Temperaturemaintainedinthecircuitsduringcomfortperiods.
Normallyduringdaytime.
Compensationtemperature
Ameasuredtemperatureinfluencingtheflowtemperature
reference/balancetemperature.
Desiredflowtemperature
Temperaturecalculatedbythecontrolleronbasisoftheoutdoor
temperatureandinfluencesfromtheroomand/orreturn
temperatures.Thistemperatureisusedasareferenceforthe
control.
Desiredroomtemperature
Temperaturewhichissetasthedesiredroomtemperature.The
temperaturecanonlybecontrolledbytheECLComfortcontroller
ifaroomtemperaturesensorisinstalled.
Ifasensorisnotinstalled,thesetdesiredroomtemperature
howeverstillinfluencestheflowtemperature.
Inbothcasestheroomtemperatureineachroomistypically
controlledbyradiatorthermostats/valves.
Desiredtemperature
Temperaturebasedonasettingoracontrollercalculation.
Dewpointtemperature
Temperatureatwhichthehumidityintheaircondensates.
VI.GU.L2.02
©Danfoss|2017.09|189
OperatingGuideECLComfort210/296/310,applicationA275/A375

Other manuals for Danfoss ECL Comfort A368

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ECL Comfort A368 and is the answer not in the manual?

Danfoss ECL Comfort A368 Specifications

General IconGeneral
BrandDanfoss
ModelECL Comfort A368
CategoryController
LanguageEnglish

Related product manuals