User manual ERC 113 refrigeration controller
Application matrix
Stand-alone Output Input
Application ERC type DO1 DO2 DO3 DO4 S1 (C1) S2 (C2) S3 (C3) Di (C4)
Standard beverage cooler ERC 113C Comp Fan Lamp Control Defrost
Condenser or
ambient light
Door
Sub-zero beverage cooler ERC 113D Comp Heater Fan Lamp Control Defrost
Condenser or
ambient light
Door
Out-door beverage cooler ERC 113D Comp Heater Fan Lamp Control Condenser Ambient light Door
No frost freezer w. glass-door ERC 113D Comp Heater Fan Lamp Control Defrost
Condenser or
ambient light
Door
CFF refrigerator ERC 113C Comp Fan Lamp Control Defrost Condenser Door
CFF freezer ERC 113D Comp Heater Fan Lamp Control Defrost Condenser Door
NOTE:
• select only one function per input, e.g. condenser sensor or ambient light sensor
• make sure that the accessory you select has a matching connector to the input, e.g. a sensor for input S2 must have C2 connector
• condenser sensor or light sensor are optional and can be omitted
• defrost sensor is mandatory when electrical heater is used for defrost. For natural defrost it can be omitted
Remote spindle Output Input
Application ERC type DO1 DO2 DO3 DO4 S1 (C1) S2 (C2) S3 (C3) Di (C4)
Standard beverage cooler ERC 113C Comp Fan Lamp Control
Condenser or
ambient light
RSP01 Door
Sub-zero beverage cooler ERC 113D Comp Heater Fan Lamp Control Defrost RSP01 Door
Out-door beverage cooler ERC 113D Comp Heater Fan Lamp Control
Condenser or
ambient light
RSP01 Door
No frost freezer w. glass-door ERC 113D Comp Heater Fan Lamp Control Defrost RSP01 Door
CFF refrigerator ERC 113C Comp Fan Lamp Control Defrost or condenser RSP01 Door
CFF freezer ERC 113D Comp Heater Fan Lamp Control Defrost RSP01 Door
NOTE:
• select only one function per input, e.g. condenser sensor or ambient light sensor
• make sure that the accessory you select has a matching connector to the input, e.g. a sensor for input S2 must
• have C2 connector condenser sensor or light sensor are optional and can be omitted
• defrost sensor is mandatory when electrical heater is used for defrost. For natural defrost it can be omitted
Remote display Output Input
Application ERC type DO1 DO2 DO3 DO4 DO5 S1 (C1) S2 (C2) S3 (C3) Di (C4) S4 (C1) S5 (C2)
Standard beverage
cooler
ERC 113C Comp Fan Lamp Control Condenser
Ambient
light
RD107 Defrost Door
Sub-zero beverage
cooler
ERC 113D Comp Heater Fan Lamp Control Condenser
Ambient
light
RD107 Defrost Door
Out-door beverage
cooler
ERC 113D Comp Heater Fan Lamp Control Condenser
Ambient
light
RD107 Defrost Door
No frost freezer w.
glass-door
ERC 113D Comp Heater Fan Lamp Control Condenser
Ambient
light
RD107 Defrost Door
CFF refrigerator ERC 113C Comp Fan Lamp Control Condenser
Ambient
light
RD107 Defrost Door
CFF freezer ERC 113D Comp Heater Fan Lamp Control Condenser
Ambient
light
RD107 Defrost Door
NOTE:
• select only one function per input, e.g. condenser sensor or ambient light sensor
• any input at RDI07 can be chosen for control, defrost, condenser, ambient light or door, if it is more convenient for cable routing
• make sure that the accessory you select has a matching connector to the input, e.g. a sensor for input S2 or S5 must have C2 connector
• condenser sensor or light sensor are optional and can be omitted
• defrost sensor is mandatory when electrical heater is used for defrost. For natural defrost it can be omitted
• the relay in RDI07A (DO5) can be used for heater, fan, lamp or alarm, and can be used instead of DO2 - DO4
30