STEP 4: select sensor type o06
The display automatically shows sensor selection parameter o06”.
Press SET to select the sensor type.
The display shows the default value (eg. n10 flashing).
Choose sensor type by pressing UP/DOWN (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) and press SET to confirm.
NOTE: all sensors must be the same type.
STEP 5: congure DO4 output o36
The display automatically shows theo36 parameter to configure DO4 output. (Available only in 4 relays model).
Select light “Lig or alarm ALA as per the application and press SET to confirm.
The display returns to normal display mode and the control is started.
5.3| Menu Structure
1) Parameter groups
2) Parameter name
3) Value
Scroll through the
parameter groups
SET: press for 3 seconds to access
status, setup and service
Password (if enabled)
Status input
Configuration
Main switch
Application
Sensor type
DO4 configuration
(only for 4 relays model)
Application 0
Application
1-2-3-4-5-6
Application
1-2-3-4-5-6
SET
Scroll through the
parameter names
SET