FP715SI
6
GB
Not Used
Gravity
5/2 Day
7 Day
Sw.1
Sw.2
Sw.3
Sw.4
Not Used
Pumped
7 Day or 24 Hour
24 Hour
Before mounting the unit, ensure the 4 DIL switches on the rear have
been moved to the required settings.
Tick the INSTALLER SETTING box on the inside fl ap label to notify user
in which mode their unit is set (24hr, 5/2 day or 7 day).
3.2 DIL Switch Settings
INSTALLER SETTING
24 Hour
5+2 Day
7 Day
4.0 Advanced Programming Options
To enter advanced programming press PROG, + and DAY/HOL
together and hold for 5 seconds.
Option 1 - (3 or 2 On/Off s per day)
Use + or - to change between 3 or 2 on/off s each day.
Option 2 - (Disable or enable auto time change)
Press NEXT, then use + or - to change between auto time change
enabled to auto time change disabled.
3
2
3 on/off s each day (Factory setting) 2 on/off s each day
Auto time change enabled (Factory setting) Auto time change disabled