Class ID 0xF5 Interface Object
Attribute Access Rule Name Data Type Description of Attribute Parameter In
frequency
converter
1 Get Status DWORD Interface status -
2 Get Configuration Capability DWORD Interface capability flags -
3 Get/Set Configuration Control DWORD Interface control flags -
4 Get
Physical Link Object STRUCT of: Path to physical link object -
Path size UINT Size of Path -
Path Padded EPATH Logical segments identifying the physical
link object
-
5 Get/Set
Interface Configuration STRUCT of: TCP/IP network interface configuration. -
IP Address UDINT The device’s IP address. 12-01
Network Mask UDINT The device’s network mask. 12-02
Gateway Address UDINT Default gateway address 12-03
Name Server UDINT Primary name server 12-06 [0]
Name Server 2 UDINT Secondary name server 12-06[1]
Domain Name STRING Default domain name 12-07
6 Get/Set Host Name STRING Host name 12-08
Table 8.10 Instance Attributes
Appendix MCA 121 EtherNet/IP
MG.90.J3.02 - VLT
®
is a registered Danfoss trademark 49
8 8