Component Replacement Procedures
■ Component Replacement Procedures
Control Module: MCD3007 ~ MCD3132
Step 1. Undo fixing screws (2) and remove lower
terminal cover.
Step 2. Undo fixing screws (4) and lift off Control
Module.
NB!
Lift the control module straight off.
DO NOT Pivot.
Step 3. Fit new Control Module in reverse order.
Control Module: MCD3185 ~ MCD3800
Step 1. Undo fixing screws (4) and remove front
cover.
Step 2. Undo fixing screws (4) and lift off Control
Module.
NB!
Lift the control module straight off.
DO NOT Pivot.
Step 3. Fit new Control Module in reverse order.