Product Specications
RET2000B-RF RX1-S
Operating Voltage
2.5 – 3 VDC
(2xAA alkaline batteries)
230Vac 50/60Hz
Output Relay - 1 x SPDT Type 1B
Switch rating - 3A (1) at 230Vac
Output - Volt free
Setting temp. range 5-30°C (cooling 16-36°C) -
Operating temp. range 0-45°C
Battery lifetime 2 years -
Max. range 30 metres
Operating frequency 433.92MHz <1mW ERP
IP Rating IP20 IP40
Control On-O / Chrono Proportional selectable
Operating modes Heating / Cooling selectable
Construction EN 60730-2-9 EN 60730-1
Control pollution situation Degree 2
Rated impulse voltage - 2.5kV
Ball pressure test 75°C
Dimensions H84 x W84 x D35 H84 x W84 x D28
Software classication A
Important note RF products: Ensure that there are no large metal objects, such as
boiler cases or other large appliances, in line of sight between the transmitter and
receiver as these will prevent communication between thermostat and receiver.