8. Unscrew the 2 T10 screws holding the control card
EMC shield (4 screws if MCO is installed).
8a If MCO is installed, remove the MCO ribbon
cable.
9. Remove the control card EMC shield.
1T10 screws
2EMC shield
Illustration 1.7 Screws and EMC Shield
10. Unscrew the 3 T10 screws and remove them.
11. Gently remove the control card from the upper-right
socket. Avoid overbending and contact with
electronic components.
1Control card
2T10 screws
Illustration 1.8 Control Card and T10 Screws
Re-assemble the new control card in reverse order.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on
order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss
and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss A/S
Ulsnaes 1
DK-6300 Graasten
vlt-drives.danfoss.com
*MI93A102*
MI93A102130R0788 03/2017

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals