Mains Supply 525-690 V AC
FC 302
P37K P45K P55K P75K P90K
High/ Normal Load* HO NO HO NO HO NO HO NO HO NO
Typical Shaft output at
550 V [kW]
30 37 37 45 45 55 55 75 75 90
Typical Shaft output at
575 V [hp]
40 50 50 60 60 75 75 100 100 125
Typical Shaft output at
690 V [kW]
37 45 45 55 55 75 75 90 90 110
Enclosure IP21 D1 D1 D1 D1 D1
Enclosure IP54 D1 D1 D1 D1 D1
Enclosure IP00 D3 D3 D3 D3 D3
Output current
Continuous
(at 550 V) [A]
48 56 56 76 76 90 90 113 113 137
Intermittent (60 s
overload)
(at 550 V) [A]
77 62 90 84 122 99 135 124 170 151
Continuous
(at 575/690 V) [A]
46 54 54 73 73 86 86 108 108 131
Intermittent (60 s
overload)
(at 575/690 V) [A]
74 59 86 80 117 95 129 119 162 144
Continuous KVA
(at 550 V) [KVA]
46 53 53 72 72 86 86 108 108 131
Continuous KVA
(at 575 V) [KVA]
46 54 54 73 73 86 86 108 108 130
Continuous KVA
(at 690 V) [KVA]
55 65 65 87 87 103 103 129 129 157
Max. input current
Continuous
(at 550 V ) [A]
53 60 60 77 77 89 89 110 110 130
Continuous
(at 575 V ) [A]
51 58 58 74 74 85 85 106 106 124
Continuous
(at 690 V) [A]
50 58 58 77 77 87 87 109 109 128
Max. cable size, mains,
motor, load share and
brake [mm
2
(AWG)]
2x70 (2x2/0)
Max. external mains fuses
[A]
1
125 160 200 200 250
Estimated power loss
at 600 V [W]
4)
1299 1398 1459 1645 1643 1827 1350 1599 1597 1891
Estimated power loss
at 690 V [W]
4)
1002 1071 1071 1251 1251 1392 1392 1648 1650 1951
Weight,
enclosure IP21, IP54 [kg]
96
Weight,
enclosure IP00 [kg]
82
Efficiency
4)
0.97 0.97 0.98 0.98 0.98
Output frequency 0 - 600Hz
Heatsink overtemp. trip
90°C
Power card ambient trip
75°C
* High overload = 160% torque during 60 s., Normal overload = 110% torque during 60 s.
Table 5.4
General Specifications
VLT
®
Automation Drive FC 300 Operating Instructions
98 MG33U402 - Rev. 2013-12-16
55

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals