PROBLEM SOLUTION
Vacuum stops running Thermal overload has been tripped:
1. Turn the vacuum off and disconnect
vacuum cleaner from power source.
2. Empty the canister, if needed.
3. Allow the unit to cool.
4. Plug the power cord into an appropriate
outlet and turn on/off switch to the ON
position (
) to test. If vacuum will not
restart call 1-800-4-D
EWALT (1-800-
433-9258).
Dust comes out while
vacuuming
Check for proper installation of the filters.
Ensure filters are not damaged; replace if
necessary.
Ensure filter seals are in place and are
secure.
Automatic filter
cleaning is not
working
Listen for the solenoid clicking to ensure
the filter cleaning mechanism is working.
Power tool does
not turn on the dust
extractor.
Ensure tool is plugged into the tool outlet
on the dust extractor.
Ensure the on/off switch is in the ON
position (
).
Ensure the tool control switch is in the ON
position (
).
SPECIFICATIONS
DWV010
Volts 120 V ~
Hertz 60
Rated Current 15 A per UL1017
Nominal Motor Current 11.8 A
Capacity 8 gallon (30.2 liters)
Weight 21 lbs. (9.5 kg)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeWalt DWV010 and is the answer not in the manual?

DeWalt DWV010 Specifications

General IconGeneral
Power SourceCorded
Tank Capacity8 gallons
Hose Diameter1.25 inches
Filter TypeHEPA
Airflow130 CFM
Voltage120V
TypeWet/Dry
Included AccessoriesHEPA Filter

Related product manuals