6.4 Indicator lights
“POWER ON” INDICATOR
On the Dometic ush switch panel, a steady green “Power On” light (g.
3
3, p. 6) indicates when
electrical power to the toilet is activated. A momentary ashing green light indicates when ush
mode is changing.
“FULL TANK” INDICATOR
The Dometic ush switch panel includes a red “Full Tank” light (g.
3
4, p. 6) to indicate when the
holding tank is full and should be pumped out. When the red light is illuminated, electrical power to the
toilet automatically shuts off to prevent possible overlling of the holding tank.
6.3 Changing flush modes
MasterFlush toilets offer two ush settings to help manage water consumption:
Normal flush – Uses 0.85 gal. (3.2 liters) per ush. Adds water to bowl after every ush.
Dry Bowl flush – Uses 0.45 gal. (1.7 liters) per ush. Does not add water to bowl after ush.
To change from Normal to Dry Bowl ush setting, press “Flush” switch for about ve seconds. When
“Power On” light (g.
3
3, p. 6) begins ashing, release “Flush” switch. Flush mode has been
changed to Dry Bowl setting. Change mode to Normal ush by following the same procedure.
6.5 Bidet operation
(toilet models with
integrated bidet only)
1. Turn on bidet faucet by
turning handle away from
toilet (g.
4
).
2. Adjust water temperature by
turning handle up for warm
water and down for cool
water (g.
5
).
3. Use electronic “Flush” switch
to clear toilet bowl during
and after bidet use.
Caution! Hazard of Flooding
Be sure to shut bidet faucet off completely after use.