If the inverter has stopped operation because of
one of the previously described reasons, a manual
restart can be done.
To manually restart the inverter, switch off at the
device switch or press the On/Off button
(fig. 3, page 4, 4)on the remote control until
the Check LED (fig. 3, page 4, 1) is extin-
guished. After a short waiting time, the inverter
can be restarted.
If after the reboot there is still a parameter over or
below the limit values, the start is prevented, and
the corresponding LED and acoustic signal
sequence signals a failure.
A
A
Warranty
The statutory warranty period applies. If the prod-
uct is defective, please contact your retailer or the
manufacturer's branch in your country (see
dometic.com/dealer).
For repair and warranty processing, please include
the following documents when you send in the
product:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
Note that self-repair or nonprofessional repair can
have safety consequences and might void the war-
ranty.
Disposal
Recycling products with non-replaceable
batteries, rechargeable batteries or light
sources
Overvoltage On On 4x/break On
Overtemperature On On 5x/break On
Overload warning On Off 1x short/break On
Overload Off On continuous Off
Short circuit Off On continuous Off
Input parameters Voltage range Description
Normal operation 11.5 V – 14.0 V
Optimal operation 13.0 V – 14.0 V
Low voltage warning 11.2 V – 10.7 V acoustic signal: 2x/break
Stop - low voltage warning < 10.7 V +/- 0.2 V Inverter off, acoustic signal: 2x/break
Restart - low voltage > 12.0 V +/- 0.2 V Inverter on
Stop - overvoltage > 15.0 V Inverter off, acoustic signal: 4x/break
voltage > 16 V - can cause damage to the device even
if it is not in operation
Status
Inverter/Extern
LED
Check LED Acoustic signal Output 230 V AC
NOTICE! Damage hazard
In case of overtemperature, wait 5 to 10
minutes for cooling down the device
before restart.
NOTICE! Damage hazard
In case of overload, turn off the load and
reduce the connected consumers. Avoid
further starts with overload.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic BUTTNER MT PL 300 SI and is the answer not in the manual?

Dometic BUTTNER MT PL 300 SI Specifications

General IconGeneral
BrandDometic
ModelBUTTNER MT PL 300 SI
CategoryInverter
LanguageEnglish

Related product manuals