Cleaning and maintenance CoolFreeze
16
6.13 Replacing the DC plug fuse
➤ Pull the adapter sleeve (4) off of the plug.
➤ Unscrew the screw (5) out of the upper half of the housing (6).
➤ Carefully lift the upper half of the housing off the lower half (1).
➤ Take out the contact pin (3).
➤ Replace the defective fuse (2) with a fuse with the same type and rating
(T8 A 32 V).
➤ Re-assemble the plug in the reverse order.
I
7 Cleaning and maintenance
!
A
NOTE - Internal DC fuse
There is an additional DC fuse inside the device (Automotive standard
blade fuse, 10 A). This fuse can only be replaced by an authorised repair
centre.
WARNING!
Always disconnect the device from the power supply before you clean
and service it.
NOTICE! Risk of damage
•
Never clean the cooler under running water or in dish water.
•
Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooler.