21. Technical Data
Gas operation butane (propane):
Rated thermal loading: 151 W (133 W)
Min. thermal loading: 143 W (85 W)
Connected load, gas: 11 g/h (9,5 g/h)
Connection pressure: 28-30/37 mbar
Categorie: I
3+
Climat class: 'N'
Electr
ic operation:
220V-240V (mains) 50 Hz: 110W
12V (car battery): 110W
Capacity: 61 Ltr.
Refrigerant: 357g. H
2
O + 168g NH
3
The refrigeration cycle has been checked for leaks.
22. Environmental protection information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen compound) is used as a refrigerating
agent in the refrigeration unit.
The ozone-friendly cyclopentane is activated as a motive agent for the PU foam
insulation.
Sodium chromate is used for corrosion protection (less than 2 weight % of the
coolant).
This appliance complies with the following EEC directives:
LVD-Directive 2006/95/EC
EMC-Directive 2004/108/EC
Gas-Directive 90/396/EEC
CE-Directive 93/68/EEC
RoHS-Directive 2002/95/EC
WEEE-Directive 2002/96/EC.