- 15 -
TROUBLESHOOTING
Symptom Check/Remedial action
Refrigerator or freezer is not
cold enough
Is the plug rmly connected to the socket? Is the socket switched on?
Check the socket by plugging in another appliance.
Defective fuse?
Fit a new fuse.
For refrigerators equipped with thermostat - check if it is properly set.
Is the refrigerator level? Because of its operation it is important to keep an
absorption refrigerator level.
Heavy frost build-up on evaporator ns? To prevent frost buildup, which can reduce
efciency, do not leave the unit’s door open longer than necessary.
Has the overheating protection been triggered or not? (Must be checked by a qualied
service technician.)
Is there a power failure? Are the fuses are intact for the AC supply and control system?
Has the door been closed properly causing the inside temperature to rise to quickly?
Overpacked refrigerator? The unit will have to work harder if the refrigerator is stuffed
and results in higher cabinet temperatures. Arrange the food in the unit to allow for free
air circulation.
Is the burner dirty, damaged or not properly located under the ue tube?
Is the burner jet clogged?
Is the ue bafe inserted properly in the ue tube?
Is the LP gas pressure low at burner?
Set the main regulator to regulate the pressure so it does not drop below 11 inches water
column at pressure tap.
•
•
•
•
•
•
•
•
•
•
•
•
•
Odors from fumes: Dislocated burner
Damaged burner
Dirty ue tube
•
•
•
The refrigerator does not work in
gas operation mode
Gas bottle empty?
Change the gas bottle
Air in the gas pipe?
Remove the air by switching the refrigerator on and off 3-4 times.
•
•
The refrigerator is quality-guaranteed but we are not responsible for any failures caused by improper adjustments. If the refrigera-
tor is still not working properly, contact your nearest Service Center. State the problem, model, product- and serial-number. These
details are stated on the data label inside the compartment.
If you run into a problem, refer to the troubleshooting table below.