A Series Diesel Engine Engine Replacement and Testing 226
Adjust the length of the cable/rod to the mechanical
shut down lever so there is stop-to-stop movement.
Note : Make sure the air intake and exhaust pipe
connections are tight and free of leaks.
Fill the engine with the required amount of lubricating
oil.
6.5 Liters [1.85 gal]
Note : Check the oil level after the engine has run for
2 to 3 minutes. Oil held in the oil filter and oil
passages will cause the oil level in the oil pan
to lower.
Fill the cooling system with a mixture of 50% water
and 50% ethylene-glycol base antifreeze.
Refer to the equipment manufacture’s specifications
for radiator capacity.
Engine Only Coolant Capacity
3.0 Liters [0.7 gal]