4 | Dräger RVP - Communication | Middelborg/Olsson | November 2011
There are 5 different norms of network cable in the world.
As shown in the table below each type uses different colours. The cable type in the manuals of
the RVP's and this presentation refer to the EIA/TIA 568B norm.
Dräger RVP - Communication
Network Cable
Cable pair
Pin
EIA/TIA 568A
EIA/TIA 568B
IEC
REA
DIN 47.100
1 4/5 blue/white blue/white blue/white white/blue white/brown
2
3/6
white/green
red/orange
turquoise/violet
green/yellow
3
1/2
white/green
white/orange
black/grey
white/orange
grey/pink
4
7/8
white/brown
white/brown
yellow/brown
turquoise/violet
blue/red