Form 6 AST control reference
Reference Material
Form 6 AST Control
Read equipment manufacturer’s manual and this material before using this product.
Failure to do so can result in death, severe personal injury, and equipment damage. G164.0
COOPER POWER
SERIES
ote:N This reference card only applies to the standard, factory-
default AST control.
Refer to the installation instructions included with this control
for additional information.
Control / recloser status
Status of the recloser and control are easily viewed via the operator
panel. Press any key to wake the operator panel.
CONTROL OK: Normally on. The CONTROL OK LED will
extinguish if certain battery, RAM, ROM, AC, Power Supply, and/
or RIF alarms are active.
CONTROL POWER: An illuminated CONTROL POWER LED
indicates there is adequate VTC voltage to successfully trip (or
close) the mechanism. It does NOT indicate the presence of AC
or battery power.
CONTROL LOCKOUT: On only when the control is in a Locked-
Out state. It does NOT indicate the recloser is open.
RECLOSER OPEN: On only when the Recloser is Open.
RECLOSER CLOSED: On only when the Recloser is Closed.
AST status indicators
AST READY indicates that the AST is in the normal
configuration and is ready to transfer if required. This LED will
blink when the AST is timing to begin a transfer.
AST ACTIVE indicates that the AST has transfered to the
alternate source. This light will blink if the AST is timing to
transfer back to the preferred source.
LOAD SERVED indicates that the critical load is being served by
one of the two sources.
LOCAL PREFERRED indicates that this recloser is connected to
the preferred source for the load.
REMOTE PREFERRED indicates that that the remote recloser is
connected to the preferred source for the load.
REMOTE SOURCE VOLTS OK indicates that the remote
recloser has acceptable voltage on the source side.
REMOTE DEVICE CLOSED indicates that the remote recloser
is closed.
REMOTE DEVICE OPEN indicates that the remote recloser is
open.
Navigating the LCD display
NOTE: The LCD display panel contrast is field-adjustable to allow
for various mounting heights and applications. Press the MENU
key and then press the (+) or (–) key to increase or decrease the
contrast.
LCD FUNCTION KEYS (F1, F2, F3, F4): The four LCD menu
function keys activate specific menu commands. When a
command appears in the LCD display directly above one of the
four LCD menu function keys, press the key to accept/select the
command.
NOTE: Function keys are not active in all menus.
MENU: The MENU key displays the root menu. It also returns
the display to the previous menu each time it is pressed.
ENTER: The ENTER key is used for the following:
Confirm a settings modification.
Confirm a selection from within a MENU.
( + and - ) Keys: are used to step through values when in the
MODIFY / SETTINGS mode.
ARROW Keys: Navigate vertically through the displayed MENU
using the UP and DOWN arrow keys; arrow keys are located just
below the display. In some menus, the cursor position can be
moved horizontally using the LEFT and RIGHT arrow keys.
RESET ALARMS: Press the ALARMS hotkey, move the cursor
( > ) to the left of the RESET ALARMS menu item, press the
ENTER key, then the F4 function key.

Other manuals for Eaton KA146W5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton KA146W5 and is the answer not in the manual?

Eaton KA146W5 Specifications

General IconGeneral
BrandEaton
ModelKA146W5
CategoryCables and connectors
LanguageEnglish

Related product manuals