Grade Sensor Calibration | Appendix TRSM0940
Grade Sensor Calibration
The Transmission Electronic Control Unit (TECU) uses a
Grade Sensor to calculate vehicle incline or grade. The
grade position is used for the Hill Start Aid (HSA) feature
and provides information to assist in vehicle launch and
shifting. The Grade Sensor is internal to the TECU. Fault
Code 68 FMI 13 indicates a Grade Sensor Calibration is
required.
The Grade Sensor is calibrated via ServiceRanger or an
Operat
or-Triggered Procedure.
Note: Verif
y the following prior to performing the Grade
Sensor Calibration with ServiceRanger or the Operator Trig-
gered Procedure:
1. Vehicle must be on level ground be
fore initiating
the grade sensor calibration.
2. Verify the suspension is fully aired.
3. Verify the suspension is set to proper height.
4. Ground surface must be within +/-
0.5% grade
(0.28 degrees) from level.
5. Maximum allowable grade
is +/- 0.5 degrees
(0.87% grade) from level.
ServiceRanger Procedure
1. Set vehicle parking brake and chock wheels.
Note: Verify vehicle is
parked on level ground and the
suspension is fully aired (if equipped) and set to proper
ride height.
2. Key on with engine off.
3. Connect ServiceRanger.
4. Go To “Service Routines.”
5. Select "Start" Grade Sensor Calibration.
6. Follow on-screen prompts.
Operator-Triggered Procedure
1. Set vehicle parking brake and chock wheels.
Note: Verif
y vehicle is parked on level ground and the
suspension is fully aired (if equipped) and set to proper
ride height.
2. Key on with engine off.
3. Select Low mode with the Transmission Driver
Interface Device.
4. Select Upshift Requests until the Display indicates
"6".
5. Depress and hold the Accelerator Pedal to the floor.
6. When the Display indicates a "Down Arrow", release
the Accelerator
Pedal.
7. When the Display indicates "0", select Ne
utral
mode.
8. Key off and allow the TECU to perform a complete
po
wer down sequence.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton UltraShift PLUS FO-16E310C-LAS and is the answer not in the manual?

Eaton UltraShift PLUS FO-16E310C-LAS Specifications

General IconGeneral
BrandEaton
ModelUltraShift PLUS FO-16E310C-LAS
CategoryMicrophone system
LanguageEnglish

Related product manuals