12
4.1.4. CAN function
There are 10 options from 5K to 1000K. Users can also fill
in any baud rate value by themselves.
Normal: The CAN port can respond to the received CAN
frame normally;
Listen only: The CAN port works in the monitor mode and
does not respond;
The values that can be filled are: 1 to 39. When the CAN
Subcontracting
time interval
(ms)
The values that can be filled in are: 12 to 255. When the
CAN port does not receive a new data frame within the time
defined by the "packet time interval" (unit is ms), and the
number of sub-packet frames is not reached, the previous
All data frames received and not yet sent are encapsulated
into an Ethernet packet and sent to the network port.
This option is only valid in TCP working mode. It
determines whether to clear the data in the CAN port Buffer
after the connection is established. If not, the data in the
Buffer will be sent after the connection is established. If
clear when TCP connection is selected, the saved CAN
buffer will be cleared when the TCP connection is
established.
The upper limit and lower limit of the received
standard frame ID set by the user together determine
the standard frame ID range to be received.
Standard frame
lower limit
The upper limit value and lower limit value of the
received extended frame ID set by the user together
determine the range of the extended frame ID to be