Check unit for loose nuts, bolts and screws daily.
IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold
the unit firmly.
STARTING COLD ENGINE
1. Move ignition switch (A) to START/RUN position.
2. Push purge bulb (B) 3-4 times (or until fuel is visible in fuel return line).
3. Close choke (C) (move choke lever down) and pull starter handle
(D) until engine fires.
4. Open choke (C) and if necessary, restart engine.
NOTE
Allow engine to warm up before use.
STARTING WARM ENGINE
1. Move ignition switch (A) to start, pull starter handle (D) 1-3
times and engine should start. Do not use choke (C).
NOTE
If engine does not start after 3 pulls, use cold start procedures.
STOPPING ENGINE
1. Release throttle trigger (E) and allow engine to run at idle for a
few minutes.
2. Move ignition switch (A) to "STOP" position.
WARNING DANGER
If engine does not stop, shift choke lever to closed position.
Check and repair ignition switch before starting engine again or
serious personal injury may result.
D
B
D
C
C
D
A
E
A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Echo PB-2400 and is the answer not in the manual?

Echo PB-2400 Specifications

General IconGeneral
BrandEcho
ModelPB-2400
CategoryBlower
LanguageEnglish

Related product manuals