sTarTIng warm engIne
The starting procedure is the same as Cold Start except DO NOT close
the choke.
1. Throttle Position Lever
Move throttle position lever (A) to start/idle detent position
(
).
2. Purge Bulb
Pump purge bulb (C) until fuel is visible and ows freely in the
clear fuel tank return line.
3. Recoil Starter
Pull recoil starter handle (D) and engine should start.
NOTE
If engine does not start after 5 pulls, use cold start procedures.
sToppIng engIne
1. Throttle Position Lever
Move throttle position lever (A) to idle detent position(
) and
allow engine to return to idle before shutting off engine.
2. Move throttle lever (A) to " " (Stop) position.
WARNING
If engine does not stop when throttle lever is moved to STOP posi-
tion, close choke - COLD START position - to stall engine. Have
your ECHO dealer repair stop switch before using blower again.