PB-580H/T MAINTENANCE
X7505200705 35
© 12/2017 ECHO Inc.
ENGLISH
Overheating and engine seizure can
occur when:
Air intakes are blocked,
preventing cooling air from
reaching the cylinder.
Dust and grass build up on the
outside of the cylinder. This build
up insulates the engine and
prevents the heat from leaving.
Removal of cooling passage
blockages or cleaning of cooling fins
is considered “Normal
Maintenance.” Any failure attributed to lack of maintenance is not warranted.
Cleaning Grill
1. Brush accumulated debris from intake grill between backpack frame
and blower housing.
Cleaning Cylinder Fins
1. Remove spark plug.
2. Remove starter
3. Remove engine cover.
4. Clean cylinder fins (A) to allow
cooling air to pass freely
5. Assemble components in
reverse order.
Exhaust System
Spark Arrestor Screen
Level 2.
Carbon deposits in muffler will cause a drop in engine output and
overheating. Spark arrestor screen must be checked periodically.
Parts Required: Spark Arrestor Screen, Gasket
A