7. Recommended spare parts
Technical Data Booster/Main station.
Advanced* Proff.**
Water
Unit. 3 (4 kW) 3 (4 kW) 4 (5.5 kW) 7 (10 kW)** 8 (11 kW)*
Max. Outlet pressure. bar 25 25 25 22 25
Consumption during rinsing. 1) L/min 90 90 120 210 240
Consumption during foaming. L/min 30 30 40 80 80
Min. supply pressure. bar 2 2 2 2 2
Max. supply pressure. bar 8 8 8 8 8
Min. water supply. L/min 100 100 135 265 265
Max. water temp. °C 70 70 70 70 70
Pipe dimension inlet Ø inch 1.1/4" 1.1/4" 1.1/4" 2" 2"
Pipe dimension outlet Ø inch 1.1/4" 1.1/4" 1.1/4" 2" 2"
Electricity
Supply voltage V
3/PE 400 V ±10%
Frequency Hz 50/60 Hz 48 0%…62 +0%
Motor load (kW) kW 4 4 5.5 10 10
Installation to EN 60204-1
Nominal current A 10.6 10,6 14.2 27 27
Fuse A 16 16 20 35 35
L1, L2, L3, PE mm2 2.5 2.5 2.5 6 6
General
Sound level ISO 11202 dB Below 70 Below 70 Below 70 Below 70 Below 70
Dimensions mm
1070 x 550 x 375 785 x 550 x 375 1074 x 557 x 382 1074 x 557 x 382 990x535x364
Weight (kg) kg 85 60 75 75 80
All specications are based on 5 bar supply pressure
Note:
* Pump pressure 20 bar + inlet pressure max. 25 bar
** Pump pressure 20 bar + inlet pressure max. 22 bar
1) 1 user per 30l/min.
8. Specications
The recommended spare parts are marked with * in the spare part manual.

Other manuals for Ecolab Chameleon PLUS BW3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Chameleon PLUS BW3 and is the answer not in the manual?

Ecolab Chameleon PLUS BW3 Specifications

General IconGeneral
BrandEcolab
ModelChameleon PLUS BW3
CategoryWater Pump
LanguageEnglish

Related product manuals