CMUip-2212 Cabinet Monitor Unit
Operations Manual
Eberle Design Inc. Page 23
Not Active ................................................................................ less than 30 Vrms
AC Control Monitors
MC Secondary Status
Active ....................................................................................... greater than 166 Vrms
Not Active .................................................................................... less than 154 Vrms
DC Control Monitors
Local Flash Status, MC Coil Status, FTR Coil Drive, CB Trip Status
Active ........................................................................................... greater than 44 Vdc
Not Active ......................................................................................... less than 42 Vdc
Front / Rear Door Switch
Active ........................................................................................... greater than 13 Vdc
Not Active ......................................................................................... less than 11 Vdc
Mains Power Fail Monitor
HV+ Mains Restore ..................................................................... greater than 174 ± 2 Vrms
HV+ Mains Dropout .......................................................................... less than 164 ± 2 Vrms
DC Voltage Monitors
+24 Volt Monitor
Active ........................................................................................... greater than 22 Vdc
Not Active ......................................................................................... less than 18 Vdc
+12 Volt Monitor
Active ........................................................................................... greater than 11 Vdc
Not Active .......................................................................................... less than 9 Vdc
Logic Inputs
External Test Reset, Serial Bus #1 Disable, Address 0, Address 1
Not Active (False) ........................................................................ greater than 16 Vdc
Active (True) ...................................................................................... less than 8 Vdc
CMU Temperature
Accuracy ..................................................................................................................... ± 6
o
C
5.2 TIMING
Cabinet Power Supplies
Fault ........................................................................................... greater than 500 ms
No Fault ........................................................................................... less than 200 ms
Typical ............................................................................................................ 400 ms
Conflict
Fault ........................................................................................... greater than 500 ms
No Fault ........................................................................................... less than 200 ms
Typical ............................................................................................................ 350 ms
Serial Bus #1 Error
Fault ........................................................................................... greater than 600 ms
Serial Bus #3 Error
Fault ........................................................................................... greater than 300 ms
Multiple
Fault ........................................................................................... greater than 450 ms
No Fault ........................................................................................... less than 200 ms
Typical ............................................................................................................ 400 ms
Lack of Signal Inputs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EDI CMUip-2212 Series and is the answer not in the manual?

EDI CMUip-2212 Series Specifications

General IconGeneral
BrandEDI
ModelCMUip-2212 Series
CategoryController
LanguageEnglish

Related product manuals