TEMPERATURE RISE AT SPECIFIED FLOW RATE, DEGREES F:
TURN-ON 3.0 4.0 6.0 8.0 12.0 20.0 25.0 30.0
MODEL GPM GPM GPM GPM GPM GPM GPM GPM GPM
AP032208 1.0 73 55 36 27 18 10 8 7
AP036208 1.0 82 61 41 29 20 12 9 8
AP041208 1.0 93 70 47 35 23 13 11 9
AP054208 1.5 123 92 61 46 31 18 14 12
AP064208 2.5 146 109 73 55 36 22 17 15
AP036480 1.0 82 61 41 31 20 12 9 8
AP039480 1.0 89 67 44 33 22 13 11 7
AP048480 1.0 109 82 55 41 27 16 13 11
AP054480 1.5 123 92 61 46 31 18 14 12
AP063480 2.5 143 108 72 53 36 22 17 14
AP072480 2.5 147 123 82 61 41 25 20 16
AP096480 2.5 * * 109 82 54 33 26 22
AP108480 2.5 * * 99 92 61 37 30 25
AP126480 2.5 * * 143 107 72 43 34 29
AP144480 2.5 * * * 122 82 49 40 34
AP130600 2.5 * * * 111 73 44 35 30
AP150600 2.5 * * * 128 85 52 40 35
5) CONTROL FEATURES
BEFORE USING THIS CONTROL, MAKE SURE ALL PRIOR INSTALLATION STEPS HAVE
BEEN PROPERLY COMPLETED, ELECTRICAL POWER IS ON AND WATER IS PRESENT
IN THE HEATER.
PUSH BUTTON FLOW CHART
1) The SETPOINT
TEMP or ACTUAL TEMP screen can be
selected for display
as the home screen. Either of these
screens will remain on the display when the backlight timer
expires.
2
) There is a 5 minute time delay built into the control.
Regardless of which screen is being displayed, after 5
minutes of inactivity, the display will revert to the SETPOINT
TEMP
screen.
3
) The 4 push buttons are used to control the operation of
the heater. The LEFT and RIGHT buttons shift the display
from one screen to another. The DOWN and UP buttons
may change the values within selected screens.
4) As an example, when the screen displays SETPOINT
TEMP, the desired hot water temperature will increase 1
degree for each press of the UP button and decrease 1
degree for each press of the DOWN button. Note that
minimum and maximum
setpoint temperatures are
established at the factory.
9
OR
ACTUAL
TEMP 75F
SETPOINT
TEMP120F
SETPOINT
TEMP120F
SETPOINT
TEMP120F