7
\
ProSeries XTP models are approved for zero clearance to combustible surfaces such as plywood.
Above clearances are recommended for service and installation.
1. Locate the best position to mount the unit. Check clearances around the unit according to the diagram below. Measure from
the top, bottom, left & right sides of the bracket to ensure proper clearances.
Hang the slide lock wall mounting bracket utilizing the appropriate anchors for the wall in at least 4 hole locations.
10" Top Clearance
8" Clearance
8" Clearance
18" Clearance
Upright
Installation
8"
Clearance
Measure 13" from top edge for 10" Top Clearance
Measure 30.5" from bottom edge for 18" of clearance
8"
Clearance
Alternate
Installation