Fault Possible causes Rectifi cation
Motor does not start a) Internal terminals disconnected
b) Safety lock-off defective
c) Scarifi er housing clogged
d) Safety plug is not connected
e) Battery is not correctly inserted
f) Battery is empty
a) By customer service workshop
b) By customer service workshop
c) Change the scarifying depth if
necessary; clean the housing so
that the spike drum can move freely
d) Connect safety plug (see 6.)
e) Remove battery and insert again
(see 5.)
f) Use a charged battery
Engine performance
drops
a) Soil is too fi rm
b) Housing clogged
c) Roller badly worn
a) Change working depth
b) Clean housing
c) Replace roller
Imprecise scarifying
result
a) roller worn
b) Wrong working depth
a) Replace roller
b) Correct working depth
Motor stops sud-
denly
a) Battery is overloaded
b) Battery is empty
a) Switch the equipment off and on
again. If this happens often, use a
battery with higher capacity (Ah)
b) Use a charged battery