P/N 316439221
Once the cooktop has been removed the manifold panel and burner box can be removed to access
the manifold, burner control valves, and ori ce holder assemblies.
Removing Manifold Panel
Removing Manifold Panel
Remove the four mounting screws on the
underside of the manifold panel. Remove the
burner valve control knobs by pulling them
straight forward off the valve shafts.
Removing Burner Box
Removing Burner Box
Remove the three ¼” hex head screws that
secure the manifold assembly to the burner box.
Carefully lower the manifold assembly on to the
Carefully lower the manifold assembly on to the
top of the oven insulation.
top of the oven insulation.
Guide Pin
Hinge Bracket
Using a
3
/16” socket wrench or nut driver unscrew
and remove the two front guide pins. Next remove
the left and right rear hinge brackets.
Remove the four sheet metal screws that secure
the back edge of the burner box to the rear main
panel and lift the burner box off the range.
Next remove the three ¼” hex head screws
securing the top of the manifold panel and
remove the panel.
Mounting Screws
Remove Screws
With the manifold panel removed the surface
burner ignitor switches and harness are
accessible. The wire harness and switches are
replaced as a complete assembly.
To remove the switches and harness from the
burner valves loosen the wire twist ties that
secure the wire harness to the manifold pipe. Pull
forward to unsnap the switch housing from the
valve. When replacing the switches make sure
that the switches snap securely and lock to the
valve body. The slack in the wire harness should
lay under the manifold tube and secure with the
wire twist ties as shown in the photo.
Manifold Mounting
Screws
Burner Ignitor Switches and Harness
With the burner box removed the manifold pipe, surface burner valves, burner ori ce assemblies and
door latch hook assembly are accessible for service.
Removing & Replacing Manifold Panel and Burner Box

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Electrolux 30” GAS FREESTANDING RANGES and is the answer not in the manual?

Electrolux 30” GAS FREESTANDING RANGES Specifications

General IconGeneral
BrandElectrolux
Model30” GAS FREESTANDING RANGES
CategoryRanges
LanguageEnglish

Related product manuals