BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Semi-rapid 1,9 0,8 65 138
Auxiliary 1,0 0,45 46 73
9.6 Gas burners for NATURAL GAS G2.350 13 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Multi Crown 3,9 1,75 200
Semi-rapid 1,8 0,8 126
Auxiliary 1,1 0,45 98x
Installation kit to be ordered from
Authorised Service Centre.
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification CGS6436BX,
EGS6436RK,
EGS6436SX,
EGS6436WW,
KGS6436BX,
LGS6436SX
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid 60.8%
Right rear - Semi-rapid 63.1%
Left front - Multi Crown 56.2%
Right front - Auxiliary not applicable
Energy efficiency for the gas hob
(EE gas hob)
60.0%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
www.electrolux.com18