EasyManuals Logo
Home>Emerson>Thermostat>1F80-361

Emerson 1F80-361 User Manual

Emerson 1F80-361
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1F80-3611F80-361
1F80-3611F80-361
1F80-361
Programmable Electronic Digital Thermostat
INSTALLATION ANDINSTALLATION AND
INSTALLATION ANDINSTALLATION AND
INSTALLATION AND
OPERATION INSTRUCTIONSOPERATION INSTRUCTIONS
OPERATION INSTRUCTIONSOPERATION INSTRUCTIONS
OPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYFAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYFAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSEBEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSEBEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.PERSONAL INJURY AND/OR PROPERTY DAMAGE.
PERSONAL INJURY AND/OR PROPERTY DAMAGE.PERSONAL INJURY AND/OR PROPERTY DAMAGE.
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTIONDESCRIPTION
DESCRIPTIONDESCRIPTION
DESCRIPTION
Temperature override until next program period
Manual program override (HOLD temperature)
Temporary HOLD
°F/°C convertibility
Temperature range 45° to 90°F
RC, RH, C, W, Y, G , O and B terminals
Optional C terminal (Dual Power option)
B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
Program storage in case of power loss
2 “AA” alkaline batteries included
OperOper
OperOper
Oper
aa
aa
a
tortor
tortor
tor
::
::
:
Sa Sa
Sa Sa
Sa
vv
vv
v
e these instre these instr
e these instre these instr
e these instr
uctions fuctions f
uctions fuctions f
uctions f
or futuror futur
or futuror futur
or futur
e use!e use!
e use!e use!
e use!
Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-
stat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design heating and cooling programs that fit
your needs.
Features:Features:
Features:Features:
Features:
Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-
gramming with four separate time/temperature periods per day
Simultaneous heat and cool program storage
Preprogrammed temperature control
Backlit display
LCD continuously displays setpoint, and alternately dis-
plays time and room temperature
PRECAUTIONSPRECAUTIONS
PRECAUTIONSPRECAUTIONS
PRECAUTIONS
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment damage,To prevent electrical shock and/or equipment damage,
To prevent electrical shock and/or equipment damage,To prevent electrical shock and/or equipment damage,
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse ordisconnect electric power to system at main fuse or
disconnect electric power to system at main fuse ordisconnect electric power to system at main fuse or
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.circuit breaker box until installation is complete.
circuit breaker box until installation is complete.circuit breaker box until installation is complete.
circuit breaker box until installation is complete.
Do not use on circuits exceeding specified voltage.Do not use on circuits exceeding specified voltage.
Do not use on circuits exceeding specified voltage.Do not use on circuits exceeding specified voltage.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could causeHigher voltage will damage control and could cause
Higher voltage will damage control and could causeHigher voltage will damage control and could cause
Higher voltage will damage control and could cause
shock or fire hazard.shock or fire hazard.
shock or fire hazard.shock or fire hazard.
shock or fire hazard.
Do not short out terminals on gas valve or primary controlDo not short out terminals on gas valve or primary control
Do not short out terminals on gas valve or primary controlDo not short out terminals on gas valve or primary control
Do not short out terminals on gas valve or primary control
to test. Short or incorrect wiring will damage thermostatto test. Short or incorrect wiring will damage thermostat
to test. Short or incorrect wiring will damage thermostatto test. Short or incorrect wiring will damage thermostat
to test. Short or incorrect wiring will damage thermostat
and could cause personal injury and/or property dam-and could cause personal injury and/or property dam-
and could cause personal injury and/or property dam-and could cause personal injury and/or property dam-
and could cause personal injury and/or property dam-
age.age.
age.age.
age.
Thermostat installation and all components of the sys-Thermostat installation and all components of the sys-
Thermostat installation and all components of the sys-Thermostat installation and all components of the sys-
Thermostat installation and all components of the sys-
tem shall conform to Class II circuits per the NEC code.tem shall conform to Class II circuits per the NEC code.
tem shall conform to Class II circuits per the NEC code.tem shall conform to Class II circuits per the NEC code.
tem shall conform to Class II circuits per the NEC code.
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
ELECTRICAL DATAELECTRICAL DATA
ELECTRICAL DATAELECTRICAL DATA
ELECTRICAL DATA
Electrical Rating:Electrical Rating:
Electrical Rating:Electrical Rating:
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load1.5 Amps Maximum Total Load
1.5 Amps Maximum Total Load1.5 Amps Maximum Total Load
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATATHERMAL DATA
THERMAL DATATHERMAL DATA
THERMAL DATA
Setpoint Temperature Range:Setpoint Temperature Range:
Setpoint Temperature Range:Setpoint Temperature Range:
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:Operating Ambient Temperature Range:
Operating Ambient Temperature Range:Operating Ambient Temperature Range:
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:Operating Humidity Range:
Operating Humidity Range:Operating Humidity Range:
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:Shipping Temperature Range:
Shipping Temperature Range:Shipping Temperature Range:
Shipping Temperature Range:
-4°F to 149°F
APPLICATIONSAPPLICATIONS
APPLICATIONSAPPLICATIONS
APPLICATIONS
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
Millivolt systems
DO NOT USE WITH:DO NOT USE WITH:
DO NOT USE WITH:DO NOT USE WITH:
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
PART NO. 37-6621CPART NO. 37-6621C
PART NO. 37-6621CPART NO. 37-6621C
PART NO. 37-6621C
Replaces 37-6621B
0745
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
WARNING
!
CAUTION
!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson 1F80-361 and is the answer not in the manual?

Emerson 1F80-361 Specifications

General IconGeneral
BrandEmerson
Model1F80-361
CategoryThermostat
LanguageEnglish

Related product manuals