1569005010 XR30-60-70T QRG EN r1.2 2021.05.10 XR30-60-70T 1/2
FULL TOUCH – XR30-60-70T
Please put this label near the controller in order to keep
all information you need at your fingertips!
SAFETY INFO
• This manual is part of the product and should be kept near the instrument for easy and quick reference.
• The instrument shall not be used for purposes different from those described hereunder. It cannot be used as a safety device.
• Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality.
• In case of failure or faulty operation, contact the local distributor or “Dixell S.r.l.” with a detailed description of the fault.
• The instrument must not be opened.
• Check the application limits and the correct power supply voltage before proceeding.
• Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high
atmospheric humidity to avoid condensation
• Warning: disconnect the power supply and all other electrical connections before any kind of maintenance.
• Observe the maximum current value which can be applied to each relay (see Technical Data).
• Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
USER INTERFACE
This screen shows temperature value, measurement unit and active alarms only. This is the first screen after power
on or after exit from other status.
This screen shows available functions. Activated function will blink when this screen is visualized.
This screen shows activated functions and regulation outputs (compressor, ventilators)
This screen enables the modification of the Set point or parameters.
These screens enable the modification of all parameter values.
This screen enables the modification of the Set Point value.
This screen is for creating the parameter label by swiping-up every single part of the label itself (first, second and third
char).
Press a specific area of the screen
with a finger for 1 sec
Switch ON / Switch OFF: when in Virtual Keyboard, use this to turn on/off a
specific function. When in Programming mode, use this to select a parameter or a
parameter value.
Press any place of the screen with a
finger for 3 sec
Enter / Save: use this to enter Programming mode or Parameter menu and to
save modifications. When in Virtual Keyboard, use this on the “ONOFF” to switch
OFF and ON the device.