3 Wiring
Topics covered in this chapter:
Options for wiring
Connect 4-wire cable
Connect 9-wire cable
3.1 Options for wiring
The wiring procedure you follow depends on which electronics option you have.
See Table 3-1 for the wiring options for each sensor electronics option.
Wiring procedures by electronics optionTable 3-1:
Electronics option Wiring procedure
Integral transmitter No wiring required between sensor and transmitter. See the transmitter
installation manual for wiring the power and signal cable to the transmitter.
MVD
Direct Connect
No transmitter to wire. See the MVD Direct Connect manual for wiring the
power and signal cable between the sensor and the direct host.
Core processor See Connect 4-wire cable.
Junction box See Connect 9-wire cable.
CAUTION!
Make sure the hazardous area specified on the sensor approval tag is suitable for the
environment in which the sensor will be installed. Failure to comply with the requirements for
intrinsic safety in a hazardous area could result in an explosion.
CAUTION!
Fully close and tighten all housing covers and conduit openings. Improperly sealed housings
can expose electronics to moisture, which can cause measurement error or flowmeter failure.
Inspect and grease all gaskets and O-rings.
3.2
Connect 4-wire cable
Wiring
Installation Manual 7