11
2.4 Battery voltage control parameters
Battery parameters
Below values are measured in the 12V/25 ºC system; please double the values in the
24V system.
Battery type
Voltage
parameters
Sealed
GEL
User
Over Voltage
Disconnect Voltage
16.0V
16.0V
9~17V
Charging Limit
Voltage
15.0V
15.0V
9~17V
Over Voltage
Reconnect Voltage
15.0V
15.0V
9~17V
Equalize Charging
Voltage
14.6V
--
9~17V
Boost Charging
Voltage
14.4V
14.2V
9~17V
Float Charging
Voltage
13.8V
13.8V
9~17V
Boost Reconnect
Charging Voltage
13.2V
13.2V
9~17V
VLVR Low voltage
reconnect voltage
12.6V
12.6V
9~17V
Under Voltage
Warning Reconnect
Voltage
12.2V
12.2V
9~17V
Under Voltage
Warning Voltage
12.0V
12.0V
9~17V
VLVD Low Voltage
Disconnect Voltage
11.1V
11.1V
9~17V
Discharging Limit
Voltage
10.6V
10.6V
9~17V
Equalize Duration
120 minutes
--
0180 minutes
Boost Duration
120 minutes
120 minutes
10180 minutes
The following rules must be observed when modifying the parameter values
in User for a lead-acid battery.
A Over Voltage Disconnect Voltage > Charging Limit Voltage Equalize Charging
Voltage Boost Charging Voltage Float Charging Voltage > Boost Reconnect
Charging Voltage.
B Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
C Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage Discharging Limit
Voltage.
D Under Voltage Warning Reconnect Voltage>Under Voltage Warning VoltageDischarging