4) Ethernet Port
DIP-SW1
No. Setting
1 OFF Settable
2 OFF Fixed at OFF
3 OFF Fixed at OFF
4 OFF Fixed at OFF
5 OFF Fixed at OFF
6 OFF Fixed at OFF
7 OFF Fixed at OFF
8 OFF Fixed at OFF
Set DIP-SW1-1 (Power button function).
If this DIP Switch is ON, the power button is disabled.
Make other settings in accordance with the settings described above.
2.3 Port Information
1) Port information when serial port is used
The port information that can be set with the SetupPOS utility is as follows.
Item Setting range
Baud rate [bps] 2400,4800,9600,19200,38400
*1
,
57600
*1
,115200
*1
Bit length [bit] 8
Parity NONE, ODD, EVEN
Stop bit [bit] 1
Handshake DTR/DSR
Output buffer length [byte] 32 to 1024
Output interval time [ms] 0 to 9999
*1