11 For Professional Technical Support call 1-844-241-5521
Deep Well Pump Replacement
MATERIALS REQUIRED (NOT INCLUDED)
Additional items needed QTY Internet #
Additional items needed QTY Internet #
(A) 1-1/4 in. Foot Valve 1 205618048
(M) 10 in. Tank Tee (or recommened size based
on tank size)
1 205618015
(B) 1-1/4 in. Priming Tee 1 100120387 (N) 1/4 in. Plug 1 100204497
(C) 1 in. Female PVC adaptor 4 100347423 (O) 2 in. Pressure gauge 0-100 psi 1 205962440
(D) 1/2 in. pressure relief valve 1 205149183 (P) 1-1/4 in. Male Adaptor 4 203811644
(E) 1-1/4 in. Schedule 80 PVC Pipe (or Flex Pipe) 100182626 (Q) 1 in. Schedule 80 PVC Pipe of Flexible Pipe 202280936
(F) 1-1/4 in. Coupling (required if using PVC pipe) 203811387 (R) 1 in. PVC elbow 1 100346841
(G) 1/2 in. x 1/2 in. Drain valve 1 205812176 (S) 1 in. PVC coupling 100343722
(H) 4 in. Well Seal 1 300494432 (T) 1 in. x 3 in. nipple 2 100191626
(I) 1-1/4 in. Flexible PVC Coupling (required is using
PVC pipe)
1 100055392 (U) 1-1/4 in. x 4 in. Galvanized Steel Nipple 1 100209692
(L) 1 in. Male Adaptor 1 100344011
(V) 1 in. Flexible PVC Coupling (required is using
PVC pipe)
1 202245805
WARNING: All joints and connections must be AIRTIGHT. A single leak will prevent the proper operation of the pump. Wrap thread tape
clockwise on all threaded connections. For all non-threaded connections, you must use PVC purple primer and PVC cement to ensure airtight
seals. Measure all pipe lengths before attaching.
NOTE: The ejector kit from the factory is for shallow well application. For deep well installation, the venturi tube (B) (J32P-18/#11) and nozzle
(C) (#02) have to be installed.
REPLACING AN EXISTING PUMP
WARNING: Risk of electric shock. Can shock, burn or kill. Disconnect power to pump before working on pump or motor.
1. Drain and remove the old pump and the ejector in the well. Check pipe for scale, lime, rust, etc., and replace it if necessary.
NOTE: Your old ejector (in the well) can’t be properly matched to your new pump. You must use the included ejector to your new pump.
2. Refer the following instruction to finish the new pump installation.
NEW DEEP WELL INSTALLATION (4 in. OR LARGER WELL)
1
Removing the pre-assembled nozzle
and venturi
Removing the pre-assembled ejector first then removing the pre-
assembled nozzle and venturi.
NOTE: SKU 1001 480 251, Turn the venturi tube (#13)
counter clockwise. Remove the venturi tube (#13) and nozzle
(#04) with an O-ring from the ejector.
NOTE: SKU 1001 480 255, Turn the venturi tube (#14)
counter clockwise. Remove the venturi tube (#14) and nozzle
(#04) with an O-ring from the ejector.