7 For Professional Technical Support call 1-844-241-5521
Operation
NOTE: Make certain you unwind the garden hose completely. Kinks in the hose will restrict the pump, preventing it from priming, which is
the first step to pumping water. This pump has water detector sensors. As long as the water level is over 2 in., the pump will automatically
start operating.
Place the pump on the pool cover or solid base that you would like to remove water. And plug the pump power plug into a 115V outlet,
protected with a 10 AMP fuse or circuit breaker.
WARNING: Do not handle pump or pump motor with wet
hands or when standing on wet or damp surface, or in water.
WARNING: Do not let plug fall in water and do not stand in
water while the pump is plugged in.
NOTE: The pump will not start working unless water level is
over 2 in. The pump continues to run until water is pumped
down to 3/4 in. deep, and then it stops. If the water level is
not over 2 in., the pump will not start.
Airlock
This pump is a centrifugal utility pump, designed to efficiently remove water. However, it cannot move air. If air is trapped inside the pump
(a condition called “airlock”), the pump cannot pump water out even though the pump is completely submerged. This pump has an airlock
hole. Air flows out through the anti-airlock hole, eliminating the airlock so that the pump can operate properly. If debris blocks the
anti-airlock hole, unplug the pump, reinstall the pump, and restart the pump.
If the pump is suddenly dropped into water, it might take a couple minutes to squeeze air out through the anti-airlock hole. Alternately, drain
the water out of the garden hose, keep the end of the hose out of the water, and plug in the power cord, restarting the pump.
CAUTION: This hole is for anti-airlock purposes. Leakage of
air or water is NORMAL and NECESSARY. DO NOT REMOVE OR
BLOCK THIS HOLE!
Care and Cleaning
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug
the pump and allow time for it to cool after periods of extended use.
CAUTION: When temperatures drop below freezing remove pump from service and store indoors to protect pump from
damage due to ice.
Do
Do Not
When the power is disconnected, inspect the pump inlets and
remove all debris, then plug the pump back into the
grounded outlet.
Disassemble the motor housing. This motor has NO
repairable internal parts, and disassembly may cause
leakage or dangerous electrical wiring issues.
Lift up the pump by the power cord.