Diode Test
1. Set the Function switch to the diode position.
2. Press the FUNC key until the symbol appears on the LCD.
3. Insert the black test lead to the COM input jack and the red test lead to the input
jack.
4. Connect the test lead tips to the diode. A typical diode forward voltage drop will
indicate 0.3 to 0.7V. The reverse drop will indicate "OL", indicating high impedance.
Proper diode check should include both forward and reverse tests.
Frequency Measurement
1. Set the Function switch to the Hz position.
2. Press the FUNC key until the "Hz" symbol appears on the LCD.
3. Insert the black test lead to the COM input jack and the red test
lead to the Hz input jack.
4. Connect the tips of the test leads to the device to be measured
(see diagram).
5. Read the frequency value in Hz on the LCD.
Duty Cycle Measurements
Follow the steps as for Frequency measurements with the following exception: Press the
“Hz/%” key until the “%” symbol appears on the display.
Capacitance Measurement
1. Set the Function switch to the position.
2. Press the FUNC key until the "nF" symbol appears on the LCD.
3. Insert the black test lead to the COM input jack and the red test
lead to the red input terminal.
4. Connect the tips of the test leads to the device to be measured
(see diagram).
5. Read the capacitance value on the display.
NOTE: When making very low capacitance measurements, use the
REL function to zero any stray capacitance.
RED REDBLACK BLACK
FORWARD TEST REVERSE TEST
www.burntec.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments 380926 and is the answer not in the manual?

Extech Instruments 380926 Specifications

General IconGeneral
BrandExtech Instruments
Model380926
CategoryMultimeter
LanguageEnglish

Related product manuals