Operation
The display and front panel buttons provide a means to view the status of the datalogger, observe
the current Temperature or Relative Humidity and to view the MAX and MIN values recorded during
a recording session. The datalogger setup conditions such as sample rate, temperature units and
alarm values are programmed via the provided software. Refer to the software Help File on the disk
for those procedures.
1. Press the MAX/MIN button to view the recorded Max and Min values with the time they were
recorded. If, while in this mode, no button is pressed for 40 seconds the display will
automatically return to the real time display.
2. The Time and Date display will automatically toggle every 10 seconds
3. When downloading the data to the PC, -PC-will be displayed on the LCD. After the download
is complete, the datalogger will display the last value recorded, but it will stop recording. The
logger needs to be re-set from the software to begin a new recording session.
4. The “REC” LED will flash at the programmed rate when the unit is datalogging.
5. Alarm function: When the measured value exceeds the programmed upper or lower limit and
the LED function is selected in the software, the ALM LED will flash one time per minute.
6. If “-LO-“ is displayed, the temperature and humidity sensors need attention.
7. The datalogger should be placed upright when in use.
8. If used in low temperature, high humidity environment, the datalogger should be placed upright
in a dry area to remove any condensation before downloading the data.
9. Battery life can be extended by leaving the datalogger connected to a pc.
10. Disabling the REC and ALM LEDs will extend battery life.
11. The LCD display will stop functioning at very low temperatures and will become active again
when the unit is returned to higher temperatures.
NOTE: The logger needs to be re-set from the software to begin a new recording session.
Combination Lock
The logger is supplied with a wall mount case and security combination lock. The
lock is shipped with a -0-0-0- code as viewed from the side with the alignment bar.
To change the code:
1. Press the release to open the lock (1)
2. Using a pointed object, press IN and HOLD the locking pin on the bottom of the
lock (2).
3. Set the new code (3) and release the locking pin

Other manuals for Extech Instruments RHT20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments RHT20 and is the answer not in the manual?

Extech Instruments RHT20 Specifications

General IconGeneral
BrandExtech Instruments
ModelRHT20
CategoryData Loggers
LanguageEnglish

Related product manuals