4.Defrosting
a. Auto Defrosting: When heat pump is defrosting, will be flashing. After defrosting, will stop
flashing.
b. Compulsory Defrosting: When heat pump is heating, press and together for 5 seconds to start
compulsory defrosting, and will be flashing. After defrosting, will stop flashing.
(Note: Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for
more than 10 minutes.)
5.Wifi setting
Please kindly check the last page.
2.3. Daily maintenance and winterizing
2.3.1. Daily Maintenance
Please don’t forget to cut off power supply of the heat pump
Please clean the evaporator with household detergents or clean water, NEVER use gasoline, thinners or
any similar fuel.
Check bolts, cables and connections regularly.
2.3.2. Winterizing
In winter season when you don’t swim, please cut off power supply and drain water out of the heat
pump. When using the heat pump under 2, make sure there is always water flow.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat
exchanger may be damaged.