3. TECHNICAL SPECIFICATION
Model
IPH15
IPH20
IPH25
IPH30
IPH35
IPH45
IPH55
IPH70
IPH70T
IPH100T
Advised pool
volume (m
3
)
15~30
20~40
25~45
30~55
35~65
40~75
50~95
65~120
65~120
90~160
Working air temp
()
-7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity
(kW)
6.5
8.1
10.0
12.1
13.5
17.5
21.0
27.5
27.3
35.5
C.O.P
15.8~7.4
15.5~7.4
16.2~7.3
15.6~6.0
16.3~6.7
16.6~6.2
16.1~6.0
16.2~6.5
16.1~6.5
16.5~5.8
C.O.P at 50%
capacity
11.3
11.2
11.3
10.8
11.2
11.4
11.0
11.5
11.5
11.2
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity
(kW)
4.8
6.0
7.0
8.1
9.5
11.5
14.5
18.0
18.0
24.2
C.O.P
8.1~4.8
7.7~5.0
8.1~4.8
7.8~4.5
8.2~4.6
8.2~4.5
8.1~4.4
8.5~4.8
8.5~4.8
8.4~4.7
C.O.P at 50%
capacity
7.0
6.8
7.0
6.5
6.8
6.6
6.5
7.0
7.0
7.2
Rated input
power(kW) at air
15°C
0.12~0.94
0.16~1.2
0.21~1.4
0.24~1.8
0.27~2.1
0.3~2.6
0.36~3.3
0.53~3.8
0.53~3.9
0.63~5.15
Rated input
current(A) at air
15°C
0.52~4.1
0.7~5.2
0.91~6.1
1.04~7.8
1.17~9.1
1.3~11.3
1.57~14.3
2.3~16.5
0.76~5.6
0.91~7.4
Power supply
230V/1 Ph/50Hz
400V/3 Ph/50Hz
Advised water
flux (/h)
2~4
2~4
3~4
4~6
5~7
6.5~8.5
8~10
10~12
10~12
12~18
Sound pressure
1m dB(A)
37.8~47.2
38.8~48.2
38.6~49.9
42.1~50.7
41.3~54.0
43.1~53.8
40.9~54.2
43.5~54.9
43.5~54.9
42.6~54.7
Sound pressure
10m dB(A)
17.8~27.2
18.8~28.2
18.6~29.9
22.1~30.7
21.3~34.0
23.1~33.8
20.9~34.2
23.5~34.9
23.5~34.9
22.6~34.7
Water pipe in-out
Spec (mm)
50
Net Dimension
LxWxH (mm)
894×359×
648
894×359×
648
894×359×
648
954×359×
648
954×359×
648
954×429×
648
954×429×
755
1084×429×
948
1084×429×
948
1154×539×
948
Net Weight
(kg)
43
45
49
50
52
63
68
90
93
117
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration system
running at least 15 hours a day.
Related parameters are subject to adjustment periodically for technical improvement without further notice. For
details please refer to nameplate.

Other manuals for Fairland IPH100T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fairland IPH100T and is the answer not in the manual?

Fairland IPH100T Specifications

General IconGeneral
BrandFairland
ModelIPH100T
CategoryHeat Pump
LanguageEnglish

Related product manuals