FOR INSTALLERS AND PROFESSIONALS
2. Wiring diagram
NOTE:
Must be hard wired, no plug allowed
For your safe use in winter, it’s strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
3. Options for protecting devices and cable specification
MODEL
IPHC150T
IPHC300T
Breaker
Rated Current A
25
48
Rated Residual
Action Current mA
30
30
Fuse A
25
48
Power Cordmm
2
5×6
16
Signal cablemm
2
3×0.5
3×0.5
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Supply
400V 50Hz
Breaker
For power supply: 400V 50Hz
Earthing
Fuse