02
-
UCBTG.A_V
1
-
DIMU
00
-
EN
CONNECTIONS
30
Replace the cover and secure it with screws.
Any damage caused by water/steam infiltration or insects, due to the machine panels
not being closed (after installation or maintenance) shall void any warranty claims.
7.2 WATER CONNECTION
The equipment is to be installed with adequate backflow protection to comply with
applicable federal, state, and local codes.
The water pressure in the supply network must be between the values indicated in the
"INSTALLATION TECHNICAL DATA" table.
If not, install a pressure reducer upstream of the appliance.
Before making the water connection, carefully clean the connection pipe. It is
advisable to let the water flow to clean the whole piping. Any impurities could
compromise the operation of the machine.
The diameter of the connections is indicated in "INSTALLATION TECHNICAL DATA"
The connection point is indicated in the "PLANT CONNECTION"
Install a shut-off valve upstream of the appliance, one for each water connection on the appliance, near the
appliance and in a position easily accessible by the user.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Firex CUCIMIX UCBTG AV1 Series and is the answer not in the manual?

Firex CUCIMIX UCBTG AV1 Series Specifications

General IconGeneral
BrandFirex
ModelCUCIMIX UCBTG AV1 Series
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals